Custom Silicone Swimming Gear Manufacturer | OEM/ODM
Laboratory-Grade Testing

Tensile & Durability Testing Protocol

Every silicone component we produce undergoes multi-stage mechanical validation -- tensile strength, elongation, rebound, bending fatigue, and real-world assembly cycles. ASTM · ISO · GB Standards · 15 Years Expertise

Silicone tensile testing in laboratory
Scope

Applicable Products & Testing Objectives

Our tensile durability protocol targets silicone swimming equipment subject to repeated stretching, flexing, and impact. The goal: validate real-world lifetime performance before mass production.

  • Verify tear & tensile resistance under cyclic loading
  • Ensure elasticity recovery after prolonged stretch
  • Validate strap-buckle assembly reliability
  • Certify compliance with FDA, CE, LFGB, RoHS, REACH

Swim Caps

Stretch resistance, seam integrity, repeated donning cycles.

Goggle Straps & Seals

Elongation, rebound, long-term UV & chlorine exposure.

Fins & Hand Paddles

Bending fatigue, flex memory, water resistance load.

Nose Clips & Earplugs

Compression recovery, grip retention, biocompatibility.

Universal tensile testing machine
Test 01

Tensile Strength Testing

Using a universal testing machine, dumbbell-shaped specimens are stretched at a constant rate until rupture. We record peak tensile force, breaking elongation, and failure mode to confirm raw material and vulcanization quality.

500
mm/min rate
≥ 9 MPa
Break Load
5 pcs
per batch
  • ASTM D412 / ISO 37 compliant specimen prep
  • Statistical analysis across 5+ samples
  • Fracture surface documented photographically
Test 02

Elongation & Rebound Resilience

Measures how far silicone can stretch and how fully it returns to its original dimensions -- critical for straps, caps, and seals that endure thousands of use cycles.

≥ 450%

Break Elongation

Specimens stretched to failure to confirm elasticity ceiling.

≤ 2%

Permanent Set

Residual deformation after 24h relaxation period.

≥ 70%

Rebound Rate

Measured via drop-ball or pendulum impact rebound.

Our proprietary curing optimization improved rebound retention by 45% after 10,000 stretch cycles -- meaning your end customers notice no loss of fit.

Test 03

Bending Cycle Fatigue

Automated flex-fatigue machines bend specimens at 180° through tens of thousands of cycles -- simulating years of folding, flexing, and twisting that goggle straps and fin blades endure.

1

50,000 Cycles @ 180°

No visible cracks, tears, or color change.

2

Low-Temp Flex Test

Performed at −20°C to validate cold-water usage.

3

Post-Cycle Dimensional Check

Tolerance drift must remain within ±0.1mm.

Bending fatigue test rig
Test 04

Strap & Assembly Pull Durability

Goggle straps, buckles, and adjustable clips are tested as assembled units. We simulate real user adjustments, repeated donning, and sudden pull loads to ensure no detachment or slippage.

Buckle Pull Force ≥ 80 N
Strap Hole Tear Resistance ≥ 25 N/mm
Repeated Adjustment Cycles 10,000+
Strap pull test
Buckle assembly test
Test 05

Training Fins & Paddle Fatigue

Dynamic water-load simulation reproduces the forces a competitive swimmer generates. We confirm long-term flex memory, foot pocket resistance, and bonding integrity.

Dynamic Water Load

Simulated 2kg thrust per cycle, 100,000 reps.

Blade Flex Memory

Angular deviation < 3° after full cycle.

Foot Pocket Bond

Overmold peel ≥ 15 N/cm, no delamination.

Chlorine Soak

500h immersion, hardness Δ ≤ 5 Shore A.

Compliance

Test Conditions & Acceptance Criteria

All tests are conducted in temperature- and humidity-controlled environments. Each batch requires a minimum 95% pass rate against defined acceptance thresholds.

ASTM D412 ISO 37 ISO 9001 FDA LFGB RoHS REACH
Parameter Condition Criteria
Tensile Strength23°C ± 2°C≥ 9.0 MPa
Elongation500 mm/min≥ 450%
Tear ResistanceDie B≥ 25 N/mm
Compression Set70°C × 22h≤ 20%
Flex Cycles180° @ 1Hz50,000 cycles
Aging70°C × 168hHardness Δ ≤ 5
Continuous Improvement

Problem Diagnosis & Design Refinement

When a test flags a weakness, our engineering team traces root cause and iterates -- from gate design and curing profile to formulation ratios.

!

Common Issue

  • • Edge tearing at strap holes
  • • Premature permanent set
  • • Delamination of overmold
  • • Micro-cracks post flex cycles
?

Root Cause Analysis

  • • Mold gate / venting review
  • • Curing time & temp recalibration
  • • Material hardness ratio audit
  • • Bonding primer re-selection
✓

Design Improvement

  • • Reinforced radius at stress points
  • • Optimized LSR curing cycle
  • • +45% toughness formulation
  • • Validated with full re-test
Request

Submit Your Durability Testing Request

Tell us about your product and target performance. We'll propose a tailored test plan and provide a formal report with every batch.

edwin@gd-yums.com
+86 134 1898 3587

We respond within 24 business hours. Your information stays confidential.